XBRate 7.0
Reinforced Concrete Cross Beam Load Rating
|
Live load reactions must be explicitly input into XBRate. This is done on the Design, Legal, and Permit Live Loads tabs of the Edit Pier window.
NOTE: Live Load Reactions are for a lane of live load. Do not multiply live load reactions with live load distribution factors, multiple presence factors, or load factors
NOTE: When integrated with PGSuper/PGSplice, the live load reactions are those associated with the longest girder line.
For each rating type, define the live load factor for the indicated limit states. In the live load grids, enter a name for the live load and a reaction. For the legal load ratings, also enter a vehicle weight that will be used in the load posting analysis.
The live loads are extracted from the girder line analysis performed by PGSuper/PGSplice. These loads are automatically applied to the XBRate pier model during the load rating analysis.
The live load factors are taken from the PGSuper/PGSplice Load Rating Options.