Define general information about the span.

Span Length

Item Description
Span Length Enter the span length measured along the alignment between the abutment/pier lines at either end of the span.

The length of the span is changed by moving all the up-station piers.

Slab Offset ("A" Dimension)

Define the slab offset for the span.

Item Description
Type Click on the combo box to define the slab offset for the entire bridge or only for this span.
Start Slab offset at the start of the span
End Slab offset at the end of the span

If the slab offset is defined by span and you click the combo box to change the slab offset to be a single value for the entire bridge: the slab offset defined for this span will be applied to the entire bridge. If the start and end slab offsets are different, you will be prompted to select one value.

Assumed Excess Camber

Enter the excess camber that is used to define the parabolic haunch depth used for computing composite section properties and/or haunch dead load. Note that this option is only available if the parabolic option is selected for computing composite section properties or haunch loading in the current Project Criteria library entry.