Use this dialog to defined the location of a strand position
Item | Description |
---|---|
Strand Type | Select the type of strand |
Allow straight strand(s) to be debonded | Check this box if these straight strands can be debonded. |
Xb,Yb | Strand position measured from the bottom center of the girder |
Xt,Yt | Strand position measured from the top center of the girder |
NOTE: X values must be positive or zero. If X is greater than zero two strand positions are created: one at (X,Y) and another at (-X,Y). This enforces the requirement that all prestressing must be symmetric about the Y axis. If X is zero, the strand position is located on the Y axis.