PGSuper
3.1
Precast-prestressed Girder Bridges
|
The Effective Prestress graph shows how the effective prestress or effective prestress force varies with both time and location for prestressing strands and post-tensioned tendons.
The graph controller, found on the left side of the graph window, is used to select the properties to be graphed and other graphing parameters.
Graph Controller Item | Description |
---|---|
Span, Girder | Select a span and girder |
Prestressing Type | Select either pretensioning or post-tensioning graph |
Permanent/Temporary | If Pretensioning is selected, select either Permanent or Temporary strands |
Interval | Select the intervals for which to plot the effective prestress. Hold [CTRL] to select multiple, nonsequential, intervals. Hold [SHIFT] and select the first and last intervals in a range. |
Stress/Force | Select if the effective prestress (fpe) or the effective prestress force (Fpe) is to be plotted |
Show Grid | Toggles the grid |
Show Girder | Toggles the girder |